background image

COPYRIGHT © 2005 MERIT INDUSTRIES, INC.

ATTENTION:

OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES

Removal/Installation of Major Assemblies -

      FORCE Radion Countertop/Fun Zone JR.

Troubleshooting Information - Installation of Major Assemblies -

FORCE Radion Countertop/Fun Zone JR.

Megatouch FORCE Technical Reference Manual

Power Supply Removal

1. Turn off and unplug the game.

2. Unlock and open the rear door.

3. Remove the screw securing the strain relief cord to the rear door, if necessary.

4. If applicable, loosen the captive screw securing the modem assembly to the game (see Figure

7), and remove the modem assembly from the game.

5. Loosen the captive screw securing the power supply assembly to the game (see Figure 8). (If

necessary, free the cables from the cable clamp on the motherboard; these cables may be
blocking the power supply. See Figure 7.) Unplug the power cord from the power supply and
remove the power supply from the game as much as possible. Disconnect the 10-pin connec-
tor harness from the back of the power supply and remove the assembly from the game com-
pletely. See Figure 8.

6. Remove the 4 screws securing the power supply to the power supply mounting bracket (3 are

located near the power inlet and 1 is near the 10-pin harness. See Figure 9. Separate the power
supply from its mounting bracket, and set this power supply aside.

Power Supply Installation

1. Place the new power supply in the power supply mounting bracket in the same manner as the

old power supply. Secure the supply to the mounting bracket with the same 4 screws. See
Figure 9.

2. Connect the 10-pin connector harness from the new power supply to its mating connector. See

Figure 8. Insert the power supply assembly in the game, making sure that the tabs on the
bottom of the bracket fit securely into their mating slots (you may have to press on the bracket
until it snaps into place). Secure the power supply assembly to the game by tightening the
captive screw. Plug the power cord into the power inlet on the new power supply. See Figure 8.

3. Replace the cables in the clamp on the motherboard (if applicable). See Figure 7. If applicable,

replace the modem assembly in the game, making sure that the 2 tabs on the bracket fit
securely in their mating slots. Secure by tightening the captive screw. See Figure 7.

4. Replace  the screw securing the strain relief cord to the rear door, if applicable.

5. Close and lock the rear door.

6. Plug in and turn on the game.

manuals/manuals_Support_Center_FORCE_20Radion_Power_20Supply_20Removal_20and_20Installation_pdf-html.html
background image

COPYRIGHT © 2005 MERIT INDUSTRIES, INC.

FIGURE 8 - POWER SUPPLY IN GAME

 

POWER SUPPLY

CAPTIVE SCREW 
SECURING POWER 
SUPPLY MOUNTING 
BRACKET 

10-PIN 
CONNECTOR 
FROM POWER 
SUPPLY 

POWER INLET 

 

SCREWS SECURING 
POWER SUPPLY TO 
MOUNTING BRACKET 
(3 PLACES; ALSO ONE 
ON BACK SIDE) 

FIGURE 7 - MODEM IN GAME

MODEM

CAPTIVE

SCREW

CABLE CLAMP ON 
MOTHERBOARD 

FIGURE 9 - POWER SUPPLY AND MOUNTING BRACKET

Troubleshooting Information - Installation of Major Assemblies -

FORCE Radion Countertop/Fun Zone JR.

Megatouch FORCE Technical Reference Manual